Technical Specifications
| Flow Rate | Approx. 50 l/min; up to 70 l/min with a variable-frequency drive—depending on the fluid and configuration |
|---|---|
| Suitable Fluids | High-viscosity and paste-like media; specific suitability based on individual design |
| Residual quantity | Less than 1%; less than 2% for drums with aseptic bags or liners |
| Drum sizes | Cylindrical: Ø 560 or 571.5 mm; conical: Ø 550 mm at top / 515 mm at bottom; small opening: Ø 545 mm at top / 571.5 mm at bottom; each available with or without an inliner |
| Chassis | 890 mm interior width; approx. 970 mm total width |
| Height | approx. 1.98 m when retracted; max. 2.707 m with standard motor or 2.805 m with stainless steel motor |
| Weight | Approx. 203 kg in the example configuration, including process unit, pump, outlet plate, gear motor, hose, and outlet elbow |
| Lifting capacity | 100 kg |
| Ambient temperature | +5 to +40 °C |
Pump, motor, and control system
| Pump principle | Eccentric screw pump for high flow rates |
|---|---|
| Connections | Discharge side DN 50; cleaning connection DN 40 |
| Stator / Seals | EPDM or NBR; materials in contact with the medium suitable for food contact in accordance with Regulation (EC) No. 1935/2004 and FDA CFR 21 are available |
| Standard motor | Gearmotor 3 kW, 230–460 V, 50–60 Hz, IP 55, IE3; 257 rpm at 50 Hz, 311 rpm at 60 Hz |
| Stainless steel motor | Geared motor 3 kW, IP 69K; 217 rpm at 50 Hz, 262 rpm at 60 Hz |
| Control | Motor protection switch or frequency converter; optional limit switch and external start/stop function |
| Compressed air | 6–8 bar, dry, for extending the follow-up plate |
| Lifting/Lowering Drive | Maintenance-free lead-acid battery, 24 V / 9 Ah; charges during operation when connected to the mains |
All performance values are application-dependent. The final design is determined based on the medium, viscosity, temperature, drum geometry, and desired delivery distance.
Operation and Performance Control
Motor protection switch or frequency converter: The control system is selected based on the required conveying capacity and integration into the process. Both options are mounted directly on the mobile system.
The motor protection switch is used to switch the motor on and off at a fixed motor speed.
- Direct and simple operation at the system
- Fixed motor speed
- Suitable for applications requiring a constant flow rate
- Protection and isolation via the main switch
![]()
The frequency inverter enables the motor to be started and stopped and its speed to be adjusted to suit the fluid and process.
- Infinitely variable motor speed adjustment
- Start and stop directly from the control panel
- Can be combined with an optional limit switch
- External start/stop function available for automated processes
![]()
Also pumps media that do not flow on their own
VISCOFLUX mobile HF was developed for applications in which high-viscosity media need to be pumped more quickly from 200-liter drums.
Tomato paste
Example value: approx. 50 l/min with a motor protection switch.
Caramel Paste
Depending on the configuration, flow rates of up to 70 l/min are possible.
Creams and Pastes
Low speeds for gentle handling.
Drums with liners
Small residual quantities, even with aseptic bags.
Two Typical Application Examples and Configurations
The actual flow rate achievable depends on the medium, temperature, hose routing, and system design. The following configurations illustrate the selection for two typical paste-like food products.
Promote 3x concentrated tomato paste
Configuration with Motor Protection Switch
approx. 50 l/min
- Process unit with 890 mm chassis for freestanding drums and universal pallets for 4 drums
- Eccentric screw pump for high flow rates
- Pressure-side connection DN 50
- Stator and seals made of EPDM—suitable for food contact in accordance with Regulation (EC) No. 1935/2004 and FDA CFR 21
- Geared motor: 3 kW, 230–460 V, 50–60 Hz, IP55, IE3, cream-white finish; speed at 50 Hz: 257 rpm; at 60 Hz: 311 rpm
- Motor control via motor protection switch
- Feed plate for conical drums
- Food-grade hose DN 50
- Discharge elbow DN 38
- Mounting bracket for discharge elbow
Dispense caramel paste
Configuration with a variable-frequency drive
up to 70 l/min
- Process unit with 890-mm chassis for freestanding drums and universal pallets for 4 drums
- Eccentric screw pump for high flow rates
- Pressure-side connection DN 50
- Cleaning connection DN 40—stator and seals made of EPDM—for food contact in accordance with Regulation (EC) 1935/2004 and FDA CFR 21
- Stainless steel gear motor, 3 kW, 230–460 V, 50–60 Hz, IP69k, IE3—speed at 50 Hz: 217 rpm; at 60 Hz: 262 rpm
- Motor control and speed regulation via frequency converter
- Follow-up plate for conical drums
- Food-grade hose DN 50
- Discharge elbow DN 38
- Bracket for outlet elbow
VISCOFLUX mobile S or HF?
The HF version extends the range of applications covered by the VISCOFLUX family. It is particularly suitable for applications where a high flow rate and low overall system height are key priorities. For applications requiring frequent complete disassembly and quick, straightforward pump cleaning, the VISCOFLUX mobile S is the ideal choice.
| Feature | VISCOFLUX mobile S | VISCOFLUX mobile HF |
|---|---|---|
| Design focus | Easy disassembly and cleaning | Maximum flow rate |
| Flow rate* | Max. 25 l/min | Max. 50 l/min; up to 70 l/min with frequency inverter |
| Emptying a 200-litre drum* | Approx. 8 minutes pumping time | Approx. 3–4 minutes pumping time |
| Speed | Approx. 700 rpm | 257 rpm at 50 Hz; 311 rpm at 60 Hz |
| Extended height | Max. 3.150 m | 2.707 m with standard motor; 2.805 m with stainless-steel motor |
| Cleaning | Easy to disassemble and clean | Cleaning connection provided; complete disassembly requires more effort |
| Batch filling | Contactless control via speed controller | Possible with an FMO flow meter |
| View Viscoflux mobile S | Request a Quote |
* Comparative value based on triple-concentrated tomato paste. The actual flow rate depends on the fluid, temperature, hose routing and system configuration. Drum changeover times are not included.
Additional Downloads
All documents and technical specifications for barrel emptying systems