MINIFLUX container pump

MINIFLUX S-41/38 | FFKM | 136 mm

Item no. 10-43029003
for horizontal use on the IBC. Made from stainless steel, FFKM seal.
Go to product details
Weight:
1.194 kg
material:
Stainless steel
FOOD approval:
no
for use in haz. area:
yes
Request quote
We will review your requirements on a individual basis. The inquiry is non-binding and will be handled personally by our expert consultants.
How can we help you?

Product details

The horizontally installed, compact MINIFLUX IBC container pump was designed for emptying IBCs via their outlet (with an S60x6 standard thread). The pump is easily connected to the outlet using a union nut. The compact design ensures a low total weight of 1.2 kg. Can be dismantled into two parts via the clamp. It is intended as an alternative to vertical drum pumps for cases where IBCs can only be accessed from above with great difficulty if at all. It does not therefore have to raised up to the container. It is also ideal if the medium’s natural outlet via the outlet tap does not provide sufficient pumping pressure for filling at speed or transferring to a container at a higher level, for example. The MINIFLUX is ideally driven by a commutator or compressed air motor. A stainless steel bracket is available as an option for fixing the commutator motor to the IBC.
  • Can also be used in locations with low ceilings
  • When IBCs are stacked one on top of another, also allows pumping from the bottom outlet
  • Considerably higher flow rate and pumping pressure compared with filling at the outlet tap using the hydrostatic pressure of the medium
  • Low overall space requirement
  • Easy to remove from IBC via union nut
  • Suited to applications in zone 1 areas subject to explosion hazards
Feature Value
Gewicht 1.194 kg
3A version no
connection outlet External thread G 1 1/4"
Outer diameter 41,00 mm
Ex-marking Ex II 2G Ex h IIB T4 Gb X
for use in haz. area yes
FDA approval no
max. flow rate 240 l/min
FOOD approval no
immersion length without mm
max. discharge head 13 mWs
material impeller ethylene tetrafluoroethylene
material seal FFKM
material Stainless steel
material shaft stainless steel
mechanical seal PTFE/carbon, oxide ceramics, S, FFKM
type impeller axial impeller 38 for higher delivery rate
viscosity max. 1000 mPas
type drum pump F 430

Media
The media listed below are intended as guidance for common applications. Other media can also be pumped – please contact our customer service for further information.

  • Acetone, 10%, 20 °C
  • Acetone, 10%, 40 °C
  • Acetone, 100%, 20 °C
  • Acetone, 100%, 40 °C
  • Allyl alcohol, 96%, 20 °C
  • Allyl alcohol, 96%, 40 °C
  • Formic acid, 50%, 20 °C
  • Formic acid, 50%, 40 °C
  • Formic acid, 85%, 20 °C
  • Ammonia solution, 100%, 20 °C
  • Ammonia solution, 100%, 40 °C
  • Ammonium nitrate, 10%, 20-40 °C
  • Ammonium nitrate, 50%, 20-40 °C
  • Ammonium phosphate, 10%, 20-40 °C
  • Ammonium sulphate, 10%, 20 °C
  • Ammonium sulphate, 10%, 40 °C
  • Amyl acetate, 100%, 20 °C
  • Amyl acetate, 100%, 40 °C
  • Amyl alcohol, 100%, 20 °C
  • Amyl alcohol, 100%, 40 °C
  • Arsenic acid, 10%, 20-40 °C
  • Arsenic acid, 80%, 20-40 °C
  • Benzaldehyde, 100%, 20 °C
  • Benzaldehyde, 100%, 40 °C
  • Benzine, 100%, 20 °C
  • Benzine, 100%, 40 °C
  • Benzole, 100%, 20 °C
  • Benzyl alcohol, 100%, 20 °C
  • Benzyl alcohol, 100%, 40 °C
  • Benzoic aldehyde, 30%, 20 °C
  • Benzoic aldehyde, 100%, 20 °C
  • Hydrocyanic acid, 100%, 20 °C
  • Hydrocyanic acid, 100%, 40 °C
  • Lead acetate, 10%, 20-40 °C
  • Borax, 10%, 20-40 °C
  • Borax, 100%, 20-40 °C
  • Boric acid, 10%, 20-40 °C
  • Boric acid, 100%, 20-40 °C
  • Brake fluid, 100%, 20 °C
  • Butanol, 100%, 20 °C
  • Butanol, 100%, 40 °C
  • Butanone (MEK), 100%, 20 °C
  • Butanone (MEK), 100%, 40 °C
  • Butyric acid, 20%, 20 °C
  • Butyric acid, 100%, 20 °C
  • Butyl acetate, 100%, 20 °C
  • Butyl alcohol, 100%, 20 °C
  • Butyl alcohol, 100%, 40 °C
  • Butylene glycol, 10%, 20-40 °C
  • Butylene glycol, 100%, 20 °C
  • Butylene glycol, 100%, 40 °C
  • Calcium chloride, 10%, 20-40 °C
  • Calcium chloride, 100%, 20-40 °C
  • Calcium hydroxide, 15%, 20 °C
  • Calcium hydroxide, 15%, 40 °C
  • Calcium nitrate, 50%, 20-40 °C
  • Chlorethanol, 100%, 20 °C
  • Chlorethanol, 100%, 40 °C
  • Chloroform, 100%, 20 °C
  • Hydrocyanic acid, 100%, 20 °C
  • Hydrogen cyanide, 100%, 20 °C
  • Hydrogen cyanide, 100%, 40 °C
  • Diesel, 100%, 20 °C
  • Diesel, 100%, 40 °C
  • Dimethylformamide (DMF), 100%, 20 °C
  • Dimethylformamide (DMF), 100%, 40 °C
  • Dimethyl phthalate (DMP), 100%, 20-40 °C
  • Iron (II) chloride, 10%, 20 °C
  • Iron (II) chloride, 50%, 20 °C
  • Iron (II) nitrate, 100%, 20-40 °C
  • Iron (II) sulphate, 20%, 20-40 °C
  • Iron (III) sulphate, 50%, 20-40 °C
  • Crude oil, 100%, 20-40 °C
  • Vinegar, 100%, 20-40 °C
  • Acetic acid, 10%, 20 °C
  • Acetic acid, 10%, 40 °C
  • Acetic acid, 25%, 20 °C
  • Acetic acid, 25%, 40 °C
  • Acetic acid, 50%, 20 °C
  • Butanedioic acid, 50%, 20-40 °C
  • Ethanol, 100%, 20 °C
  • Ethanol, 100%, 40 °C
  • Ether, 100%, 20 °C
  • Essential oils, 100%, 20 °C
  • Essential oils, 100%, 40 °C
  • Ethyl acetate, 100%, 20-40 °C
  • Ethylbenzene, 100%, 20-40 °C
  • Ethylene glycol, 100%, 20 °C
  • Ethylene glycol, 100%, 40 °C
  • Ethyl glycol, 100%, 20-40 °C
  • Fatty alcohol, 100%, 20 °C
  • Fatty acids, 100%, 20-40 °C
  • Formaldehyde, 10%, 20 °C
  • Formaldehyde, 10%, 40 °C
  • Formaldehyde, 35%, 20 °C
  • Formaldehyde, 40%, 20 °C
  • Formamide, 100%, 20 °C
  • Formamide, 100%, 40 °C
  • Fruit juices, 100%, 20-40 °C
  • Glucose, 100%, 20-40 °C
  • Glycerine, 100%, 20-40 °C
  • Glycol, 100%, 20 °C
  • Glycol, 100%, 40 °C
  • Glycolic acid, 37%, 20 °C
  • Glycolic acid, 70%, 20 °C
  • Glycolic acid, 70%, 40 °C
  • Urea, 10%, 20-40 °C
  • Urea, 33%, 20 °C
  • Urea, 33%, 40 °C
  • Heating oil, 100%, 20 °C
  • Heating oil, 100%, 40 °C
  • Hexanol, 100%, 20 °C
  • Hydrazine, 100%, 20 °C
  • Isobutyl alcohol, 100%, 20-40 °C
  • Isocyanate, 100%, 20 °C
  • Isopropanol, 100%, 20-40 °C
  • Isopropyl acetate, 100%, 20 °C
  • Caustic potash solution, 20%, 20 °C
  • Caustic potash solution, 20%, 40 °C
  • Caustic potash solution, 30%, 20 °C
  • Caustic potash solution, 30%, 40 °C
  • Caustic potash solution, 60%, 20-40 °C
  • Potassium hydroxide, 20%, 20 °C
  • Potassium hydroxide, 20%, 40 °C
  • Potassium hydroxide, 30%, 20 °C
  • Potassium hydroxide, 30%, 40 °C
  • Potassium hydroxide, 60%, 20-40 °C
  • Potassium nitrate, 10%, 20-40 °C
  • Potassium nitrate, 24%, 20-40 °C
  • Potassium permanganate, 6%, 20-40 °C
  • Potassium permanganate, 18%, 20-40 °C
  • Lime milk, 15%, 20 °C
  • Lime milk, 15%, 40 °C
  • Silicic acid, 100%, 20-40 °C
  • Copper nitrate, 25%, 20 °C
  • Copper nitrate, 25%, 40 °C
  • Copper sulphate, 18%, 20 °C
  • Copper sulphate, 18%, 40 °C
  • Linseed oil, 100%, 20 °C
  • Linseed oil, 100%, 40 °C
  • Magnesium nitrate, 25%, 20-40 °C
  • Methanol, 100%, 20-40 °C
  • Methyl acetate, 100%, 20-40 °C
  • Methyl glycol, 100%, 20-40 °C
  • Milk, 100%, 20 °C
  • Lactic acid, 10%, 20-40 °C
  • Lactic acid, 90%, 20 °C
  • Mineral oils, 100%, 20 °C
  • Mineral oils, 100%, 40 °C
  • Mineral water, 100%, 20-40 °C
  • Sodium acetate, 10%, 20-40 °C
  • Bicarbonate of soda, 10%, 20 °C
  • Bicarbonate of soda, 10%, 40 °C
  • Sodium fluoride, 4%, 20 °C
  • Sodium fluoride, 4%, 40 °C
  • Sodium hydroxide, 10%, 20 °C
  • Sodium hydroxide, 10%, 40 °C
  • Sodium hydroxide, 30%, 20 °C
  • Sodium hydroxide, 30%, 40 °C
  • Sodium hydroxide, 50%, 20-40 °C
  • Sodium nitrate, 45%, 20 °C
  • Sodium nitrate, 45%, 40 °C
  • Sodium nitrite, 50%, 20 °C
  • Sodium nitrite, 50%, 40 °C
  • Caustic soda, 10%, 20 °C
  • Caustic soda, 10%, 40 °C
  • Caustic soda, 30%, 20 °C
  • Caustic soda, 30%, 40 °C
  • Caustic soda, 50%, 20-40 °C
  • Nitrobenzene, 100%, 20 °C
  • Nitrobenzene, 100%, 40 °C
  • Nitrotoluene, 100%, 20 °C
  • Nitrotoluene, 100%, 40 °C
  • Octanoic acid, 100%, 20 °C
  • Octanoic acid, 100%, 40 °C
  • Oleic acid, 100%, 20 °C
  • Oleic acid, 100%, 40 °C
  • Oxalic acid, 10%, 20 °C
  • Oxalic acid, 10%, 40 °C
  • Paraffin oil, 100%, 20 °C
  • Paraffin oil, 100%, 40 °C
  • Perchloric acid, 20%, 20-40 °C
  • Perchloric acid, 50%, 20-40 °C
  • Perchloric acid, 70%, 20-40 °C
  • Perchloric acid, 100%, 20 °C
  • Perchloric acid, 100%, 40 °C
  • Peracetic acid, 30%, 20 °C
  • Petroleum, 100%, 20 °C
  • Petroleum, 100%, 40 °C
  • Phenol, 100%, 20 °C
  • Phenol, 100%, 40 °C
  • Phenol, 50%, 20 °C
  • Phenol, 50%, 40 °C
  • Phenol, 90%, 20 °C
  • Phenol, 90%, 40 °C
  • Phosphoric acid, 30%, 20-40 °C
  • Phosphoric acid, 50%, 20-40 °C
  • Phosphoric acid, 85%, 20-40 °C
  • Polyol, 100%, 20 °C
  • Propanol, 100%, 20-40 °C
  • Propionic acid, 50%, 20-40 °C
  • Propionic acid, 100%, 20-40 °C
  • Propylene glycol, 100%, 20 °C
  • Propylene glycol, 100%, 40 °C
  • Castor oil, 100%, 20-40 °C
  • Nitric acid, 10%, 20 °C
  • Nitric acid, 10%, 40 °C
  • Nitric acid, 30%, 40 °C
  • Nitric acid, 50%, 20 °C
  • Nitric acid, 65%, 20 °C
  • Carbon disulphide, 100%, 20 °C
  • Carbon disulphide, 100%, 40 °C
  • Sulphuric acid, 90%, 20 °C
  • Sulphuric acid, 98%, 20 °C
  • Silicone oil, 100%, 20 °C
  • Silicone oil, 100%, 40 °C
  • Cooking oil, 100%, 20 °C
  • Cooking oil, 100%, 40 °C
  • Styrol, 100%, 20 °C
  • Turpentine oil, 100%, 20 °C
  • Turpentine oil, 100%, 40 °C
  • Ink, 100%, 20 °C
  • Toluene, 100%, 20-40 °C
  • Transformer oil, 100%, 20 °C
  • Transformer oil, 100%, 40 °C
  • Glucose solution, 100%, 20-40 °C
  • Urine, 100%, 20 °C
  • Urine, 100%, 40 °C
  • Water, 100%, 20-40 °C
  • Silicate of soda, 20%, 20-40 °C
  • Hydrogen peroxide, 3%, 20 °C
  • Hydrogen peroxide, 3%, 40 °C
  • Hydrogen peroxide, 10%, 20 °C
  • Hydrogen peroxide, 10%, 40 °C
  • Hydrogen peroxide, 20%, 20 °C
  • Hydrogen peroxide, 20%, 40 °C
  • Hydrogen peroxide, 30%, 20 °C
  • Hydrogen peroxide, 30%, 40 °C
  • Hydrogen peroxide, 90%, 20 °C
  • Hydrogen peroxide, 90%, 40 °C
  • Wine vinegar, 100%, 20-40 °C
  • Tartaric acid, 100%, 20-40 °C
  • Xylene, 100%, 20 °C
  • Xylene, 100%, 40 °C
  • Zinc chloride, 20%, 20 °C
  • Zinc chloride, 20%, 40 °C
  • Citric acid, 50%, 20 °C
Datasheet
Declaration of conformity
Drawing
Inquiry form
Manual
Performance curve

Get in touch.
Find documents.

Sales & Advice

Select a pump suitable for the application
We determine the medium, flow rate, viscosity and operating environment.

Requests for quotations

Please send us your requirements
We will assess your requirements and advise you on the most suitable option.

Service & Support

Documents for planning, operation and servicing
Find user manuals, dimension sheets, technical specifications and FAQs.