Medium
Orange oil
Container
200-l-drum
Solution
Drum pump F 430 Ex S with commutator motor F 460 Ex
The Challenge
Highly flammable flavorings are transferred from drums to mixing tanks. The application takes place in a hazardous area and requires ATEX-compliant, hygienic, and precise dosing systems.
Process Flow
Reliable Conveyance and Precise Dosing in Four Steps.
The drum pump is positioned inside the 200-liter drum, and all components are connected in accordance with ATEX standards and grounded.
The collector motor drives the pump and safely delivers the orange oil to the mixing tank.
The FMO flow meter continuously measures the volume of fluid being pumped to ensure precise dosing.
Clamp connections allow for tool-free disassembly and quick, hygienic cleaning.
Result
Products used
Semi-automatic dosing system with drum pump, flow meter, and control unit, application-specific accessories available upon request.
Series 400 Drum Pumps
For pumping low-viscosity fluids from any type of container
Commutator motors
For reliable and cost-effective operation
Flow meters
For manual or semi-automatic filling of a wide variety of fluids